ZLPOWER SBL

Power protection

ZLPOWER SBL UPS systems

High frequency online, double conversion UPS: from 1 kVA tower units to modular frames up to 1200 kVA, for servers, telecom, medical and network equipment.

Exclusive distributor of ZLPOWER SBL in Saudi Arabia
ZLPOWER SBL modular UPS cabinets
  • Online double conversion
  • 0 ms transfer
  • 1 to 1200 kVA
  • SNMP smart slot

Online double conversion

The load never sees the mains

Power is turned into DC and back into a clean sine wave, all the time. When the mains fails, the battery is already on the DC bus, so there is nothing to switch.

Diagram of an online double conversion UPSStatic bypassDC busMainsRectifierInverterBatteryLoad

Mains onTransfer time 0 ms

Mains on: the rectifier feeds the inverter and charges the battery. The load runs on rebuilt power.

Product selector

Find the series for the load

Filter by form factor and power. Long run models, marked L, take external battery cabinets sized to the autonomy you need.

Series shown: 12

ZLPOWER SBL CX1K Series

Tower

CX1K Series

Capacity
1000 VA / 800 W
Phase
Single in, single out
Battery
24 V DC standard, 36 V DC long run
Dimensions
373 x 145 x 219 mm
ZLPOWER SBL EX1K Series

Tower

EX1K Series

Capacity
1 kVA
Phase
Single in, single out
Transfer
0 ms
Comms
RS232 and USB
ZLPOWER SBL CX2-3K Series

Tower

CX2-3K Series

Capacity
2 to 3 kVA
Phase
Single in, single out
Output
Pure sine wave, IEC 320
Display
LCD with smart slot
ZLPOWER SBL EX2-3K Series

Tower

EX2-3K Series

Capacity
2 to 3 kVA
Phase
Single in, single out
Control
DSP digital
Comms
RS232, USB, SNMP slot
ZLPOWER SBL EX6-10K Series

Tower

EX6-10K Series

Capacity
6 to 10 kVA
Phase
Single in, single out
Battery
Internal or external cabinet
Bypass
Automatic and manual
ZLPOWER SBL RM1-3K-E Series

Rack mount

RM1-3K-E Series

Capacity
1, 2 and 3 kVA
Output
0.8, 1.6 and 2.4 kW
Input
110-115/120 or 220-230/240 V AC
Connections
IEC 320 10 A inlet
ZLPOWER SBL RM6-10K-E Series

Rack mount

RM6-10K-E Series

Capacity
6 and 10 kVA
Output
4.8 and 8 kW
Input
220-230/240 V AC
Connections
Terminal block
ZLPOWER SBL EX310 3-10K Series

Three phase

EX310 3-10K Series

Capacity
3 to 10 kVA
Phase
Three in, single out
Input
380 / 400 / 415 V
Use
Mixed supply sites
ZLPOWER SBL EX3320 20-40K Series

Three phase

EX3320 20-40K Series

Capacity
20 to 40 kVA
Phase
Three in, three out
Input
380 / 400 / 415 V
Use
Data and plant rooms
ZLPOWER SBL RA1-3KL Series

Outdoor cabinet

RA1-3KL Series

Capacity
1 to 3 kVA
Enclosure
Weatherproof outdoor cabinet
Runtime
Long run, external batteries
Use
Roadside and remote sites
ZLPOWER SBL RA6KL and RA10KL

Outdoor cabinet

RA6KL and RA10KL

Capacity
6000 VA / 4800 W and 10000 VA / 8000 W
Input
208/220/230/240 V AC, 120 to 275 V window
Power factor
0.97 input
Output
Pure sine wave, 0.8 load PF
ZLPOWER SBL Modular UPS

Modular

Modular UPS

Capacity
15 to 1200 kVA
Input
380 / 400 / 415 V, 50 / 60 Hz
Efficiency
0.99 full load, 0.98 half load
Architecture
Parallel modules, N plus X

Specifications

Two ends of the range

CX1K, 1 kVA tower

ParameterValue
Capacity1000 VA / 800 W
Input voltage range110 to 300 V AC
Input frequency range46 to 54 Hz and 56 to 64 Hz
Input power factor0.98
Output waveformPure sine wave
Output power factor0.8
Efficiency81% line mode, 85% AC mode
Transfer time0 ms
CommunicationsRS232 and USB, SNMP optional
Operating temperature0 to 40°C

Larger series follow the same architecture at higher ratings.

Modular UPS, 15 to 1200 kVA

ParameterValue
Rated voltage380 / 400 / 415 V, 50 / 60 Hz
Input total harmonic distortionLess than 3%
Efficiency0.99 at full load, 0.98 at half load
ArchitecturePower modules in parallel, N plus X redundancy
ServiceabilityHot swap modules with self lock and full protection
Battery voltage window228 to 476 V DC, adjustable

Power modules run in parallel and swap out live.

Server room with modular UPS cabinets and network racks
Illustrative image

Typical critical loads

Rooms that cannot lose power

  • Telecom rooms

    Network cabinets and shelters that ride through grid dips and generator changeover.

  • Data rooms

    Server racks and data rooms on rack mount, three phase or modular frames.

  • Healthcare

    Medical and laboratory equipment that needs a clean, unbroken supply.

  • Retail

    Tills, card terminals and back office systems kept online through outages.

The wide input voltage and frequency window matters more in practice than the headline rating: it lets a unit ride an unstable supply and run cleanly from a generator, the normal condition on a remote site.

Management software supports Windows, Linux, macOS and major Unix systems, with remote control over SNMP across a local network or the internet.

Send the drawings, the load or the model.

We reply with a schedule, the datasheets and a delivery date from Riyadh stock.

Stock held in Riyadh · Freight, customs duty and clearance included